LIGHTSTREAM 4 / DIAGNOSTICS
Device Diagnostics
The "Diagnostics" page of the web remote shows which converters and Players of the project respond on the network, whether Art‑Net is being sent and what changed during operation.

The Art‑Net indicators in the program confirm that packets are leaving LS4. The "Diagnostics" page answers the next question — is the device at the other end alive: LS4 itself polls the network every few seconds and compares the responses with the project's devices. It is handy to keep the page open on a phone or tablet during commissioning and during a show.


How to open the page

  1. Turn on the web server with the globe button in the top bar of the LS4 window (or with the checkbox in Settings → Web Server). The web server is available with a license of 100 universes or more.
  2. Open the web remote: the "Open in browser" item in the globe menu or the QR code for a phone.
  3. Log in with the web server login and password.
  4. In the remote's header, select the "Diagnostics" tab.

If some devices have problems, a red badge with their number is lit next to the tab name — it is visible from any page of the remote.

Device polling runs the whole time the program is running, regardless of whether the page is open. If devices stop responding, the top message bar of the LS4 main window will also say so: "Art-Net devices not responding (N): …" with the names of the devices.

📷 Здесь будет скриншот: Web remote header with the "Diagnostics" tab and a red badge with the number of problems

What the page shows

To the right of the title is the summary: "All devices respond (N)", "Not responding: N of M" or "Need attention: N", and the "Check now" button — an out-of-turn poll, without waiting for the next one.

Below are three blocks.

Art‑Net

The state of sending from this computer:

Label What it means
Art-Net is being sent Output is working. Next to it — how many frames per second are actually going out of the set number, the number of sending threads and universes in the project.
Art-Net is stopped Output was turned off with the Art‑Net button or has not been started yet.
Art-Net output is muted This server is the backup in a redundancy pair, and the partner is on air now. This is the normal state.
Sending cannot keep up (red line) Fewer frames are going out than set. Fixtures may stutter: reduce the Art‑Net rate or spread the universes across several network adapters.
Another source is sending to the Art-Net network (red line) Another computer or Player is sending to the same universes. The converter listens only to the first sender — stop playback on the foreign source.

The line below says how often polling runs and when the last one was. If polling fails, the reason is stated there too: Art‑Net is not running, there is no network adapter for polling, or port 6454 is occupied by another program (then only responses addressed to this computer are visible).

Devices

A table of all converters and Players of the project: icon, name (and the Player a converter belongs to), IP and MAC, universes and number of ports, firmware version and state.

State What it means
Online The device responded to the poll; the time of the last response is shown next to it.
Checking… The first seconds after the program starts: a response is still being awaited.
Not responding No response for more than three polls in a row (about 35 seconds). Next to it — since when it has been silent.
Not bound The device in the project has neither a MAC address nor an IP — there is nothing to check with.
Not polled The device works over sACN: this protocol has no polling, and this is not an error.

One lost datagram does not move a device to "Not responding": silence longer than several polls in a row is needed for that.

Under the state there may be an explanation of the problem:

Explanation What to check
No response to ArtPoll / "has never responded since startup" Power, cable, the device's IP and subnet; the Windows firewall for UDP 6454.
Sending is not happening The converter has lost the network adapter selected for it or the adapter's address has changed — check the network card in the converter properties and in the "Network" settings.
The same address is set on another device of the project Two project devices are recorded with the same IP — one of them has a wrong address.
Address outside the adapter's subnet (in yellow) Traffic goes through a gateway. It is not included in the problem counter, but for a working system it is better to move the address into the adapter's subnet.

A non-responding device is drawn with a dimmed gray icon — it is immediately visible in a long list.

Above the table are the filters "Problems", "Not responding", "Online", "All" with the row count, and a search by name, IP or MAC. If there are problems, the page opens on the "Problems" filter, otherwise on "All". A long list is shown in portions of 200 rows, the rest with the "Show more" button.

📷 Здесь будет скриншот: The web remote "Diagnostics" page: the Art‑Net block, the "Problems" filter, in the table one "Online" device and one "Not responding" with a gray icon

Events

A log of transitions during operation: a device stopped responding, responds again, responded for the first time, sending is not happening or is restored, a foreign sender appeared, a poll failed. It shows when exactly the connection was lost — for example, brief dropouts at night that are no longer visible in the table in the morning.

How to find a device on site

Click the device icon in the table — the "Blink" command (Art‑Net LED locate) is sent to it, and compatible equipment will blink its LEDs. This is the same command as Ping from the "Fixtures" tree. For a device without an IP address the icon cannot be clicked; for a non-responding device the icon on the page does not blink in return — the command most likely will not reach it.

How polling works

  • Every 10 seconds LS4 sends one broadcast ArtPoll request through each network adapter used by the project's converters; each device responds on its own. Even on a site with hundreds of converters this is negligible traffic compared with the DMX stream.
  • Art‑Net output is not stopped or interrupted by this — it is safe to keep polling enabled throughout a show.
  • A response is matched to a project device by MAC address (as in the "Device Manager"), and if no MAC is recorded, by IP. So devices bound to hardware are recognized even after an IP change.
  • Polling is performed only by the first running copy of the program.

What to do when there are problems

What you see What to do
One device is "Not responding" Check power and cable, then the device's IP and mask. Click the icon: if the unit blinked, there is a connection and only the poll response is lost — check the firewall and subnet.
All devices are "Not responding" at once The wrong network adapter is selected, the cable is disconnected from the computer, or the firewall blocks UDP 6454. Check Settings → Network.
"Has never responded since startup" Most likely the project has a wrong IP recorded or the device is not bound by MAC — find it in network scan and bind it.
"Not bound" Specify an IP for the device or bind it to the found hardware.
All respond, but the fixtures do not light The devices are alive — check the patch, universes and DMX cables: "Art‑Net and the physical DMX output".
"Another source is sending to the Art-Net network" Find the computer or Player at the indicated address and stop playback on it.
"Sending cannot keep up" Reduce the Art‑Net rate or spread the universes across several adapters: general network settings.

For automation systems, the same data is available through the REST API.