Art-Net not sending
If the light fixtures do not react, first determine whether Light Stream 4 is actually sending Art-Net. The indicator in the program lets you immediately split the problem into two parts: packets are not leaving LS4, or packets are being sent but do not reach the needed equipment or contain wrong data.
Check the Art-Net indicator
In the LS4 top panel, find the Art-Net button and the indicator dot next to its name.
- Button dark, dot gray — Art-Net output is off. Click the left part of the Art-Net button.
- Button orange, dot blinking green — packets are actually being sent to the network.
- Button orange, dot stays gray — output is enabled, but no converter is sending packets right now. Continue with the next section.
After the program starts, Art-Net is always off, and it does not turn on by itself by default — neither when a project is opened nor when a scene is launched. Turn the output on manually with the Art-Net button; for how to restore automatic enabling when a scene is launched, see "When Art‑Net turns on by itself".
In the Fixtures panel, the state of each converter is shown by the ports on its icon:
- ports blink bright green — the converter is working and sending packets;
- ports are steadily bright green — the converter is paused;
- ports are dim green, as drawn on the icon — the converter is stopped or an error occurred, data does not go out through it.
If the green dot does not blink
1. Turn on Art-Net and check the converter state
- Click the Art-Net button in the top panel.
- Open the Fixtures panel.
- Make sure the needed converter is added to the project and is not paused.
- Check that the required universes and fixtures are assigned to its ports.
If you work on several computers, check the role of this computer. On a computer with the Master role, the local Art-Net output is disabled. Packets must be sent by the computer designated for output.
2. Select the right network card
- Click the gear on the right side of the Art-Net button.
- On the Network page, find the Network Adapter section.
- In the Network card field, select the physical Ethernet adapter to which the converter or network switch is connected.
- Make sure the Enable Art-Net option is on.
If the computer has Wi-Fi, VPN or virtual network adapters, LS4 may choose the wrong network. For Art-Net, specify the needed Ethernet card manually.
The project is open on another computer
The project's converters remember the network card of the computer on which the project was set up. If you open the project on another PC that has no such card, sending through these converters does not work. In this case a red message appears in the top message bar: it names the MAC address of the missing card and the number of converters bound to it. Select this computer's card in the Art-Net settings or in the converter properties.
If the selected card is not fast enough for the project's volume (for example, a 100 Mbit/s adapter with tens of thousands of channels), a yellow warning with a traffic estimate appears. Packet loss is possible — connect a gigabit card. Wireless adapters are not checked this way.
3. Check the converter address
When the Unicast mode is used, Art-Net is sent to the IP address specified for the converter. Check this address in the Fixtures panel.
If the converter's IP address is outside the subnet of the selected network card, LS4 shows a warning. Hover over the warning icon, then fix the converter's IP address or select the right network card.
4. Find the converter on the network
- Click the gear next to the Art-Net button.
- On the Network page, click Search.
- In the Device Manager window, open the Network Scan tab.
- Turn on Auto-search if it is off.
- Find the converter in the list and check its IP address, MAC address and state.
- Use the Ping command to check the device's availability.
- If necessary, add the found device to the project or link it to an already created converter.
If the device is not found, first check the cable, the selected network card, the IP addresses and the subnet mask.
If the indicator blinks but the fixtures do not light
A blinking green dot means that LS4 is generating and sending Art-Net packets. In this case, check the rest of the signal path:
- Make sure the fixtures are assigned to the right converter, port, universe and DMX address.
- Compare the universe numbers in LS4 with the input and output settings of the converter.
- Make sure the scene being played actually contains non-zero brightness values.
- Check that the converter or the needed output is not paused and that dimming is not enabled for it.
- For the duration of diagnostics, turn off Light Stream Player, lighting consoles and other programs or devices that may send Art-Net to the same universes.
- Check the physical DMX lines from the converter to the fixtures and the addresses of the fixtures themselves.
A blinking indicator does not guarantee that the network packet was received by a particular device. It confirms that the packet was sent by LS4 through the selected network card.
Check the license and the universe limit
If LS4 shows the critical warning "License expired", open the license management window and activate or extend it. After that, turn Art-Net on again.
Exceeding the allowed number of universes does not stop sending Art-Net packets. LS4 keeps sending all universes, but the output image is dimmed and shows a warning:
Attention! The number of universes in the project exceeds your license. The output image will be dimmed.
If the green dot blinks while the output is noticeably dimmed, check the number of universes in use and the license terms.
Check IP addresses and connection
The computer and the converter must have unique IP addresses and be in the same subnet.
Example of a correct setup:
- computer:
192.168.0.10; - converter:
192.168.0.20; - mask of both devices:
255.255.255.0.
Identical IP addresses cannot be used.
To check the network card address in Windows:
- Press Win + R.
- Enter
ncpa.cpland press Enter. - Open the properties of the Ethernet adapter connected to the Art-Net network.
- Open the properties of Internet Protocol Version 4 (TCP/IPv4) and check the IP address and mask.
Additionally check:
- the connection indication on the Ethernet ports of the computer, the switch and the converter;
- the cable and the switch port are in working order;
- the converter is reachable via Ping;
- there is no other device with the same IP address;
- Light Stream is allowed in the Windows firewall and UDP traffic passes through port
6454.
If the firewall was temporarily turned off for testing, turn it back on right after the test and create an allow rule for Light Stream or UDP port 6454.
If nothing helped
- Turn the Art-Net button off and on again.
- Restart LS4 and the converter.
- Repeat the device search on the Network Scan tab.
- Prepare for technical support:
- a screenshot of the Art-Net button and its indicator;
- a screenshot of the Network page with the selected network card;
- a screenshot of the converter in the Fixtures panel;
- the IP address and mask of the computer;
- the IP address, MAC address and model of the converter;
- the numbers of the universes and DMX addresses in use;
- the text of the warning or error, if one is displayed.
This data makes it possible to determine where the signal is interrupted: inside the project, when sending through the network card, in the network, at the converter or after its DMX output.
Категория:Устранение неполадок Категория:Art-Net Категория:Light Stream Категория:Сетевые протоколы