Devices and Network
How output works
Device types
Project and physical hardware
Adding from the library
Network scan
Adding and linking
Commands for a discovered device
Ping: finding a device on site
General network settings
When Art‑Net turns on by itself
IP addresses and subnets
Unicast and Broadcast
Player setup
Player model: V1 and V2
Ports of the built-in converter
Converter setup
Converter model
Ports and universes
Warnings
Moving and duplicating
Automatic creation
USB‑DMX
Art‑Net indicators
Workflows
Pre-launch checklist
FAQ
How output works in LS4
Data passes through several consecutive levels:
Calculates the scene
Player or interface
Physical output
512 DMX channels
Address and mode
| Level | Responsibility |
|---|---|
| LS4 | Generates channel values from scenes and effects. |
| LightStream Player | Receives the prepared project and plays it back standalone. |
| Art‑Net converter | Receives Art‑Net or sACN and converts the data to DMX or SPI. |
| USB‑DMX | Sends one DMX universe directly from the computer. |
| Port | Defines the physical output and the range of universes allocated to it. |
| Fixture | Uses the assigned universe, address and DMX mode. |
Three basic setups
- Computer → standalone converter — direct control from LS4; the converter sits at the root of the tree.
- Computer → Player → converters — preparing a standalone system; the converters are inside the Player and are part of the configuration sent to it.
- Computer → USB‑DMX — local output of a single DMX line without an Art‑Net network.
Device types
In the "Device Manager" the hardware is divided into categories.
| Category | Devices | When to use |
|---|---|---|
| Current | LS Player V2, LS Converter 2, LS Converter 6, LS Converter 8 LITE | New projects and current LightStream hardware. |
| Universal | Art‑Net Converter, USB‑DMX Interface | Third-party Art‑Net nodes and local USB interfaces. |
| Archive | LS Player V1 | Compatibility with previously installed systems. |
A LightStream product card immediately assigns the created converter a model, and with it the icon and the number of ports. The universal Art‑Net converter is added with the Custom Converter model: before adding it you can choose the number of ports — 1, 2, 3, 4, 5, 6, 8 or 16. The remaining parameters are set after creation.
Project device and physical hardware
A project device is stored in the LS4 file. It contains the name, IP address, protocol, ports, universes, DMX/SPI mode, fixture patch and Player membership. It can be fully prepared without any hardware connected.
A physical device is a real Player or converter on the local network. During a scan LS4 receives its name, IP, MAC, firmware version, number of announced ports and current state.
What linking is
Linking associates discovered hardware with a project object by MAC address. It is preserved even if the physical device's IP changes.
Adding a device from the library
Use the library when the hardware is not connected yet, the project is being prepared in advance, USB‑DMX is needed, or the physical node does not support discovery.
- Open the "Fixtures" panel.
- Click the add device button.
- Go to the "Library" tab.
- Select a category or find the model using search.
- Click the card of the device you need.
- Select the created object and fill in its properties.
If a Player is selected before adding, the new converter is created inside it. With no Player selected, the converter appears at the root of the tree as a standalone one.
USB‑DMX is not a network device and is always added from the library.
Discovering physical devices on the network
Open the "Device Manager" and select "Network Scan".
Select a network card
Specify the adapter the hardware network is connected to: Ethernet, USB–Ethernet or another dedicated interface. LS4 remembers the choice and restores it when a temporarily disconnected adapter appears again.
The tab refreshes the list automatically. The "Auto-discovery" button starts an extended scan.
The table shows the link to the project, device name, number of ports, firmware, MAC, IP, state and the linked project object. A previously discovered device may stay in the list with the status "Offline". The "Ports" column shows the number of physical outputs of the device — a device added from this row will get exactly that many ports (see "Ports and universes by port names").
Adding and linking a discovered device
In the "Project" column click "Add to Project".
Create a new device
LS4 creates a project object, transfers the available name, IP, MAC, number of ports and initial universe information, and then immediately links it to the physical device. For a LightStream player the model — Player V1 or Player V2 is filled in as well, and for a converter its model.
Ports and universes by port names
In its discovery reply a converter reports each of its universes as a separate Art‑Net port. If the ports are named following the scheme "connector name + U + universe number" — for example "HSD1U1", "HSD1U2", "HSD1U3", "HSD2U1"… (a suffix such as "-RGBW8" does not interfere) — LS4 understands the layout and assembles physical ports from them:
| In the device reply | Added to the project |
|---|---|
| 24 Art‑Net ports: HSD1U1…HSD1U3, …, HSD8U1…HSD8U3 | 8 ports, 3 universes per port |
| 16 Art‑Net ports: HSD1U1, HSD1U2, …, HSD8U2 | 8 ports, 2 universes per port |
| 6 Art‑Net ports: HSD1U1…HSD1U3, HSD2U1…HSD2U3 | 2 ports, 3 universes per port |
The layout by names is applied only when the names form a complete table: for each connector the universes run consecutively starting from the first, and all connectors have the same number of them. Otherwise the number of ports and universes is determined, as before, from the device status data — in that case check the "Number of ports" and "Universes per port" fields after adding.
Link to an existing one
Choose this option if the structure was already created manually. Probable matches by IP or name are shown first, then the other free objects of the same type. A Player is linked only to a Player, a converter only to a converter.
An object occupied by another physical link stays visible but unavailable; next to it the device it is linked to is indicated.
Change or break the link
"Change link" assigns another project object to the discovered hardware. "Unlink" removes only the MAC link: the object itself, its ports and fixtures are kept.
Commands for a discovered device
| Command | What it does |
|---|---|
| Ping | Helps physically identify a compatible device using an identification signal. The same command is sent by clicking the device icon in the "Fixtures" tree. |
| Settings | Opens the network parameters of a compatible LightStream converter; unavailable for Player and some third-party devices. |
| Open in browser | Opens the LightStream Player web interface at its current IP. |
| Synchronize settings | Sends the name and Unicast IP from the project to the linked converter. |
Converter synchronization goes from the project to the physical device. Port parameters, DMX/SPI and universe ranges are not yet transferred by this command. The project, scenes and Player configuration are transferred separately via the "Export" tab.
Ping: how to find the right device on site
Ping is an identification command. LS4 sends it to the device's IP address, and compatible hardware responds by blinking its own LEDs. This is how you check on site which physical unit in the cabinet corresponds to a project row, and whether the addresses of identical converters have been mixed up.
There are two ways to send a Ping:
- Click the device icon in the "Fixtures" tree — works for LightStream Player, for its converters and for a standalone converter. Over such an icon the cursor turns into a hand, and the row is not selected by this click.
- Select "Ping" in the "Device Manager" — in the context menu of a discovered device, see commands for a discovered device.
What happens on screen
In response, the device icon and the lamps drawn on it briefly blink orange for about two seconds. Orange means identification specifically: the green lamps on the same icon show the Art‑Net output state, and the two should not be confused.
The blinking of the icon only confirms that the command was sent. Ping goes to the IP address stored in the device properties: if the address is wrong, the device is offline or its firmware does not support identification, the icon in the program will still blink, but the hardware itself will not.
What exactly blinks in the program — the icon, the lamps or both — and the soft glow around the lamps are set in the program's service settings. By default both the icon and the lamps blink; these settings do not affect the command itself or the behavior of the device.
General LS4 network settings
Click the gear in the top Art‑Net switch or open the "Network" page in the settings.
| Parameter | Purpose |
|---|---|
| Network card | The main adapter for sending Art‑Net and discovering hardware. |
| Enable Art‑Net | Allows or completely stops network DMX output. |
| ArtSync | After the universe data, sends a synchronization packet to compatible nodes. |
| Art‑Net FPS | Network frame rate; raising it increases the load on the network and CPU. |
| Maximum number of universes per port | A technical limit of the "Universes per port" setting, not a license limit. |
| Do not enable/disable ArtNet automatically | The program does not touch the Art‑Net switch itself — neither when a scene starts nor when going to blackout. Output is turned on and off manually only. Enabled by default. |
| Do not enable Art‑Net on scene change | Starting a scene, playlist or group does not turn on Art‑Net if it is off. Going to blackout still turns the output off if the previous checkbox is cleared. Enabled by default. |
Enable ArtSync when several compatible nodes must apply a frame simultaneously. If an overload warning appears, reduce the FPS or the number of actively sent universes.
When Art‑Net turns on by itself
When the program starts, Art‑Net output is off: the Art‑Net button is not lit until it is pressed. Opening a project, "New Project" and "Close Project" do not change the output state — if it was on it stays on, if it was off it stays off.
Both checkboxes in the "Advanced settings" section of the "Network" page are checked by default, so scenes do not touch Art‑Net either. If you need automatic control, clear the checkboxes:
| "Do not enable/disable ArtNet automatically" | "Do not enable Art‑Net on scene change" | What the program does |
|---|---|---|
| checked | any | Nothing: Art‑Net is turned on and off manually only. This is the default. |
| cleared | checked | Starting a scene does not turn Art‑Net on, and going to blackout turns the output off after a few seconds. If a scene is started within those seconds, the output is not turned off. |
| cleared | cleared | Starting a scene, playlist or group turns on Art‑Net if it is off; going to blackout turns it off after a few seconds. |
IP addresses and subnets
The computer and the hardware must be in the same IP subnet.
| Setup | Computer | Device | Mask |
|---|---|---|---|
| Dedicated Art‑Net network | 2.0.0.1 | 2.0.0.10 | 255.0.0.0 |
| Ordinary local network | 192.168.10.1 | 192.168.10.20 | 255.255.255.0 |
The addresses 192.168.1.10 and 192.168.10.20 with the mask 255.255.255.0 are in different subnets.
Basic rules
- each device gets a unique IP;
- static addresses are preferable for a permanent installation;
- a gateway is usually not needed in a dedicated network;
- a wired connection is more reliable than Wi‑Fi;
- it is better to put a large system on a separate adapter;
- Art‑Net uses UDP port 6454, which must not be blocked by the firewall.
If a Unicast address is outside the subnet of the selected adapter, LS4 shows a warning: packets may go through the default gateway and load the ordinary network.
Unicast and Broadcast
| Unicast | Broadcast | |
|---|---|---|
| Where it is sent | To the IP of a specific converter | To all nodes of the subnet |
| Load | Lower, third-party nodes do not receive the stream | Higher, the whole network receives the stream |
| When to use | Permanent installation and large systems | Initial setup, a small isolated network, hardware requirements |
| What matters | The project IP must match the real address | Choose the correct adapter and subnet mask |
Unless there is a specific reason to use Broadcast, choose Unicast for a working system and assign permanent addresses to the hardware.
LightStream Player setup
Select the Player in the "Fixtures" tree.
| Parameter | Purpose |
|---|---|
| Name | Display name of the Player in the project. |
| Model | Player V1 or Player V2; sets the number of ports of the built-in converter and the device image. |
| IP address | Address of the web interface and data exchange. |
| Enable HTTPS | Use a secure connection. |
| HTTP port / HTTPS port | Connection ports to the Player. |
| Username / Password | Authorization for import and export. |
| Import / Export settings | Goes to data transfer to the Player. |
| Use internal converter | Enables the built-in output, if the model provides one. |
The internal converter is part of the Player: it cannot be moved or duplicated separately, but its universes are counted in the overall configuration and must not overlap with other converters of this Player. In the "Fixtures" tree the row of the built-in port is shown with the Player's own icon — there is no separate device behind it.
The image matches the generation: LS Player V1 and LS Player V2 have their own icon and top view, so the model is recognizable both in the "Fixtures" tree and in the synchronization window.
Linking a Player by MAC does not replace setting up the IP, HTTPS ports and credentials.
Player model: V1 and V2
The model is a property of the project device itself, not a separate type chosen once at creation. Two things depend on it:
- the number of ports of the built-in converter — Player V1 has one, Player V2 has four;
- the device image — the icon in the "Fixtures" tree and the top view in the "Device Manager".
Where to choose the model
Select the Player in the "Fixtures" tree and in the "Properties" panel open the "General" section: the "Model" row is right below the name. The options are Player V1 and Player V2. The built-in converter has no such choice: it belongs to the Player and follows its model.
How the model is determined during discovery
When adding a discovered device to the project, LS4 fills in the model itself:
- first — from the device status field, where the firmware reports "player V1" or "player V2";
- if the status does not name a model — from the number of ports: one port means Player V1, four ports means Player V2.
Changing the model of an existing device
The model is changed right in the properties: the device is converted in place, with no need to delete it and create it again. The name, IP address, credentials, position in the tree and link to the physical hardware stay the same, and the icon updates immediately.
Picked the wrong model — press Ctrl+Z. A model change is undone in a single action: the model, the removed ports and the fixtures in them are all restored.
Ports of the player's built-in converter
The ports of the built-in converter are configured individually: select it in the "Fixtures" tree and in the "Properties" panel open the "Ports" section — the "Mode and universe" row expands a table with one row per port.
| Port setting | What it sets |
|---|---|
| Mode | DMX — the ordinary output used by the program. RS485 — the port is reserved for other tasks and is not used by the program. |
| Universe | The universe number of this particular port; set arbitrarily and independently of neighboring ports. |
Modes can be set in any combination: for example, ports 1 and 3 in DMX mode and ports 2 and 4 in RS485. Universes also do not have to be consecutive — port 1 can be given universe 255 and port 3 universe 100. When a universe is changed, the fixtures of that port move along with it.
The built-in converter has no "Number of ports" or "Start universe" fields: the number of ports is set by the player model, and universes are assigned in this table. Sequential numbering from a start universe remains for ordinary converters.
A port in RS485 mode
- it has no universe — the field is empty and unavailable;
- fixtures cannot be patched to it;
- in the "Fixtures" tree the row of such a port is dimmed, and instead of a universe it says RS485 — so it is immediately clear that the port is reserved for something else, not missing.
Port modes are part of the settings exchange with the device: they go to the Player together with the "Universes and devices" section when settings are transferred, and are read back when settings are imported from the player. This way the project shows which ports of the real device are actually free for DMX.
Art‑Net converter setup
| Parameter | Purpose |
|---|---|
| Name | Name of the converter in the project. |
| Model | Converter 2, Converter 6, Converter 8 LITE or Custom Converter; sets the device icon and, for products of the line, the number of ports. See "Converter model". |
| Protocol | Art‑Net or sACN. |
| Controller type | DMX or SPI. |
| Broadcast | Switches between Broadcast and Unicast. |
| IP address | Destination address in Unicast mode. |
| Port | Network port of the protocol; for Art‑Net UDP 6454 is used by default. |
| Use custom network interface | Allows assigning a separate adapter to this converter. |
| Network card | The adapter through which this converter's stream is sent. |
| Start universe | The first universe of the first physical port. |
| Number of ports | Number of physical outputs. Shown only for the Custom Converter model: for products of the line the number of ports is set by the model. |
| Universes per port | Size of the consecutive range of each port. |
| Send empty ports | Keeps the stream for ports that have no fixtures yet. |
A separate network interface is needed if the computer is connected to several hardware networks at once. Normally the common adapter from the "Network" page is enough.
Converter model
As with the player, the model is a property of the project device itself, not a separate type chosen once at creation. Two things depend on it:
- the device image — the icon in the "Fixtures" tree and the top view in the "Device Manager";
- the number of ports — for products of the line it equals the number of connectors on the case.
| Model | Ports | Image |
|---|---|---|
| Converter 2 | 2 | LS Converter 2 icon |
| Converter 6 | 6 | LS Converter 6 icon |
| Converter 8 LITE | 8 | LS Converter 8 LITE icon |
| Custom Converter | Set by the user | Generic converter icon |
Where to choose the model
Select the converter in the "Fixtures" tree and in the "Properties" panel open the "General" section: the "Model" row is right below the name. In the expanded list the product's image is shown next to its name — so you can see the model before selecting it.
The player's built-in converter has no such row: it is part of the player and follows its model.
Custom Converter
Custom Converter means "a converter not from our line": a third-party Art‑Net node or a product not yet in the model list. It has the generic converter icon, and the "Number of ports" field stays in place — you set the number of outputs there yourself.
Model in projects from earlier versions
In projects saved before this setting appeared, the converters have no model stored. When such a project is opened, LS4 fills it in by the converter's number of ports:
| Converter ports | Model after opening |
|---|---|
| 2 | Converter 2 |
| 6 | Converter 6 |
| 8 | Converter 8 LITE |
| any other number | Custom Converter |
Ports, universes and patch do not change in the process — the model only labels the device and selects its icon. If the guess is wrong (for example, a third-party 6-port node became Converter 6), select the right model manually in the "Model" row: a model written into the project is no longer guessed afterwards.
What the model does not change
The protocol, DMX/SPI controller type, transmission mode, IP address, "Start universe" and "Universes per port" stay as you set them: the model has nothing to do with them.
Changing the model of an existing device
The model is changed right in the properties: the converter is converted in place, with no need to delete it and create it again. The name, address, position in the tree, universes and link to the physical hardware stay the same, and the icon updates immediately.
Undoing a model change
Picked the wrong model — press Ctrl+Z. A model change counts as a single action, and undoing it restores everything at once:
- the previous device model and its icon;
- the removed ports — with their names, universes and DMX/RS485 modes;
- the unpatched fixtures — each to its own port, in the previous order and with its own DMX address.
Redo (Ctrl+Y or Ctrl+Shift+Z) restores the new model in the same way. The rule is the same for the converter and the player, so checking the patch before changing the model is no longer necessary: a mistake is undone with one keypress.
How the model is determined during discovery
For a device found on the network, LS4 fills in the model by name — "Converter 2", "Converter 6", "Converter 8" — and only if it is LightStream hardware. A device from another manufacturer with exactly the same name remains a Custom Converter: the program will not draw someone else's device with a LightStream case.
The number of ports is taken from the device's own reply, not from the model: the output layout is announced by the hardware (including by the names of its ports), and anyone could have changed its name. If the model was determined incorrectly, correct it in the properties — the ports stay as they were until the model requires a different number of them.
Ports and universe ranges
Ports get consecutive ranges. If the start universe is U1, there are 3 ports and 2 universes per port, the structure will be:
| Port | Range |
|---|---|
| Port 1 | U1–U2 |
| Port 2 | U3–U4 |
| Port 3 | U5–U6 |
Changing the start universe shifts the port ranges and the fixtures in them by the same amount.
DMX usually uses one universe per physical output; exact limits depend on the model. SPI can occupy several consecutive universes. With automatic SPI addressing, LS4 moves the next fixture to a new universe if its DMX range does not fit in the current one.
The "Send empty ports" parameter is needed if the receiving hardware requires a constant stream. In other cases, disabling empty ports reduces the load.
Port and universe warnings
Duplicate universes
If one port uses U1–U2 and another U2–U3, universe U2 is assigned twice. LS4 marks such ports with a warning. The check is performed within a single Player and between standalone converters. Identical numbers on different Players are allowed: each has its own output structure.
Fixture out of range
A fixture is marked if its universe is below the start of the port, above the end of the port, or the full range of its channels does not fit before the port boundary.
IP outside the subnet
A warning on a converter means that its Unicast IP does not belong to the network of the selected adapter.
Moving and duplicating devices
An ordinary converter inside a Player can be reordered and moved between Players. The internal converter cannot be moved.
When a converter is duplicated, its settings, model, ports and fixtures are copied. LS4 gives the copy a unique name, the next free IP and a free range of universes. This also works for standalone converters.
When a Player is duplicated, its entire structure with nested converters and fixtures is copied. IP addresses become unique, and the MAC link is intentionally not copied.
You can select several Players or converters and duplicate, copy or paste them in a single operation. Deletion, duplication and model change support undo via Ctrl+Z.
Automatic structure creation
For a large unpatched project open Tools → Auto-create players and converters from unlinked….
The tool creates Players and converters, forms ports, assigns universes, distributes fixtures and issues sequential IP addresses.
Available options:
- number of Players;
- ports per converter;
- universes per port;
- DMX or SPI mode;
- protocol;
- use of the built-in converter;
- all unlinked fixtures or only the selected ones;
- start IP and IP step.
Before launch the total number of fixtures, ports and converters is displayed. After completion check the ranges, IPs, correspondence to the real models and the warnings. The operation can be undone as a single action.
USB‑DMX
USB‑DMX works locally and does not require an Art‑Net network.
- In the "Device Manager" open the "Library".
- Select "Universal" and add the USB‑DMX Interface.
- Select the created device in the tree.
- Specify the COM port or the discovered uDMX interface.
- Assign the start universe and enable the device.
- Move fixtures to its single port.
| Parameter | Purpose |
|---|---|
| Name | Name of the interface in the project. |
| Enabled | Starts and stops the output. |
| Port | COM port or the discovered uDMX. |
| FPS | Refresh rate from 5 to 30 frames per second. |
| Start universe | Universe of the single DMX port. |
When the COM port is changed, a running interface automatically stops, switches and starts again. If the device does not appear, check the driver, the USB connection, whether the COM port is occupied by another program, and the availability of a compatible driver for uDMX. If transmission is unstable, reduce the FPS.
Art‑Net indicators
The converter's output state is shown not by a separate lamp next to the icon but by the ports on the device icon itself in the "Fixtures" tree: exactly the outputs drawn on the icon light up and blink, and as many of them as the real model has — two for LS Converter 2, six for LS Converter 6, a solid strip of outputs for LS Converter 8 LITE, four for the built-in port of LS Player V2 and one for the built-in port of LS Player V1. The row of the Player itself does not show the output state: data goes out through its converters.
There can be more green connectors on the icon than outputs: only those through which data is actually flowing blink — power and service terminals stay still. On LS Player V1, for example, the lower connector protruding beyond the edge of the case blinks, while the terminal block on the panel itself does not.
| Indicator | State | Meaning |
|---|---|---|
| Top Art‑Net | Dark or gray | Network output is off. This is the state right after the program starts. |
| Top Art‑Net | Orange, dot gray | Output is allowed, but nothing is being actively sent. |
| Top Art‑Net | Orange, dot blinks green | Packets are actually going out to the network. |
| Converter | Ports blink green | The converter is transmitting data. |
| Converter | Ports lit solid green | Transmission is paused. |
| Converter | Ports gray | The converter is stopped or in an error state. |
The orange flash of the icon and its lamps has nothing to do with output: it is the response to Ping.
Recommended workflows
The project is prepared without hardware
- Create the Player and converters from the library.
- Specify the model of each Player — the number of ports of its built-in converter depends on it — and the model of each converter.
- Assign IPs, ports and universes.
- Distribute the fixtures.
- On site, run a scan.
- Link the discovered hardware to the prepared objects.
- Compare the network parameters and only then synchronize the converters.
The hardware is already connected
- Select the correct network card.
- Run a scan.
- For each device choose "Create a new device in the project".
- Check the automatically determined model, ports and universes.
- Patch the fixtures.
Standalone operation via Player
- Create or discover a Player.
- Place the converters inside it.
- Set up IPs, ports and universes.
- Check the live output from the computer.
- Transfer scenes, fixtures and configuration via "Export".
- Check standalone startup without the computer.
Pre-launch checklist
Correct adapter; one subnet; unique IPs; devices on the network; UDP 6454 not blocked.
Correct links; suitable protocol; correct ports; universes do not overlap; fixtures within ranges.
Art‑Net is on; the dot blinks; no pause and no Blackout; the scene produces a signal; the license is valid.
FAQ
The device was found, but it is not in the project
Scanning only shows the hardware. Click "Add to Project" and create a new object, or link the discovered device to an existing one.
Why did a disconnected device stay in the list?
LS4 keeps previously discovered rows and switches them to the "Offline" state. Check the "State" column.
Create a new one or link an existing one?
Create a new one if the object does not exist yet. Link an existing one if ports, fixtures and universes are already prepared in the project.
The discovered converter was added with extra ports of one universe each
The converter reports each universe as a separate Art‑Net port. LS4 assembles them into physical ports only if the ports are named following the scheme "connector name + U + universe number" (HSD1U1, HSD1U2…) and the names form a complete table — see "Ports and universes by port names". Otherwise correct "Number of ports" and "Universes per port" in the converter properties manually.
Can one object be linked to two physical devices?
No. One project object has one MAC link. Objects that are already occupied are visible in the list but unavailable.
Why did the hardware keep its old address after I changed the IP in the project?
The project IP first changes the output destination address. For a compatible linked converter use "Synchronize settings" or change the network parameters through the device window.
What does converter synchronization transfer?
In the current version — the name and Unicast IP. Ports, DMX/SPI and universes are not transferred by this command.
Remote configuration is supported only for compatible LightStream converters. For other hardware use its interface or the manufacturer's software.
I clicked the device icon — it blinked, but the hardware itself did not
The blinking of the icon only means that the identification command was sent, not that the device received it. Check the IP address in the device properties, the availability of the hardware on the network, and that the model supports identification at all. See also "Ping: how to find the right device on site".
The Player opens in the browser, but the project is not transferred
Check HTTPS, the HTTP/HTTPS ports, and the username and password in the Player properties.
Why does the player's built-in converter have no "Number of ports" field?
The number of ports of a player is determined by its model: Player V1 — one port, Player V2 — four. The ports themselves are configured individually in the "Mode and universe" table.
Where did the "Number of ports" field of the converter go?
The converter has a line model selected: Converter 2, Converter 6 or Converter 8 LITE. For them the number of ports equals the number of connectors on the case and is not a setting. If you need a different number of outputs, choose the Custom Converter model — the field will return.
I changed the model and the fixtures disappeared from the ports — how do I get them back?
Press Ctrl+Z. A model change is undone in a single action: the previous model, the removed ports and the fixtures are restored — each to its own port and with its own address. See also "Undoing a model change".
A player port is shown gray, and instead of a universe it says RS485
This port has been switched to RS485 mode: the program does not use it, it has no universe and nothing can be patched to it. To put the port back to work, select the built-in converter and in the "Mode and universe" table set the port's mode to DMX.
Why does my converter have an ordinary icon instead of a device image?
Its model is set to Custom Converter — this is how a converter not from the LightStream line is shown, and it does not affect operation. If it is a LightStream product, specify its model in the "Model" row and the icon will change. In old projects the model is filled in by the number of ports, and a converter with a non-standard number of outputs stays a Custom Converter — see "Model in projects from earlier versions". Branded images are intentionally not applied to a third-party Art‑Net device.
Why is the IP outside subnet warning shown?
The converter's address does not belong to the network of the selected adapter. Select another adapter or correct the IP and mask.
Why are identical universes highlighted with a warning?
The port ranges of one Player or of standalone converters overlap. Change the start universe or the number of universes per port.
Art‑Net is on, but the green dot does not blink
Check the state of the converters, the presence of an active scene, automatic Art‑Net control and the computer's role. Use the step-by-step Art‑Net diagnostics.
After the program starts, the Art‑Net button is not lit and the fixtures are dark
This is by design: when the program starts, Art‑Net is off, and scenes do not turn it on by default. Click the Art‑Net button on the top panel. To have the output turn on by itself when a scene starts, clear both checkboxes — see "When Art‑Net turns on by itself".
Art‑Net turns on by itself when I start a scene
This means the automatic control checkboxes are cleared on this computer — for example, they were saved as cleared in a previous version of the program. Check "Do not enable Art‑Net on scene change" or "Do not enable/disable ArtNet automatically" — see "When Art‑Net turns on by itself".
How can I tell during operation that a converter has dropped off the network?
Open the "Diagnostics" page in the web remote: LS4 polls the project's devices every 10 seconds without interrupting the output, and shows which of them do not respond and since when. The message bar at the top of the main window also reports devices that have gone missing.
Packets are going out, but the fixtures are dark
Check the patch, universe, address, port, DMX/SPI mode, cable, Blackout and the presence of another Art‑Net source.
Why does USB‑DMX not appear in the network scan?
USB‑DMX is not a network device. Add it from the library and select a local COM port or uDMX.
Related materials
- LS4 — Quick start — first launch and minimal setup.
- LS4 — Fixtures — creating, placing and addressing fixtures.
- LS4 — Art‑Net is not being sent — step-by-step output diagnostics.
- LS4 — Diagnostics — which devices respond on the network, a web remote page.
- LS4 — User guide — the other sections of the full guide.
- Converter 6 - User guide — hardware settings of the converter.
- Light Stream Player - Руководство пользователя — setting up the physical Player.