Skip to content
Light StreamWiki
← Knowledge base
Page tools

Converter Test

LIGHTSTREAM 4 / NETWORK
Converter Test
A utility for checking the installation: it sends its own Art-Net packets to any converter and any universe right from the window — without a project, without a patch and without device discovery. It helps find where the fixtures are, what their addressing is and whether the channels are connected correctly.


Why the utility is needed

A typical case is a site built with someone else's software or without documentation: the fixtures are hung, the converters are on, but nobody wrote down their IP addresses and universes, and some converters do not respond to discovery at all. "Converter Test" lets you:

  • light a specific universe at a specific IP address and see what lit up;
  • page through universes with the keys and find which one the needed strip is on;
  • make sure the channels are connected correctly: red lights red, the white channel of an RGBW fixture lights white;
  • count the pixels in a strip with a running pixel or a range;
  • send the test to a whole range of IP addresses or by broadcast when the converter's address is unknown.

The packets are generated by the utility itself and go straight to the selected address. The project's patch, scenes and effects are not involved: the utility works even with an empty project.

How to open

The Tools → Converter Test menu. Only one window opens: calling it again brings the already open one to the front.

On the left of the window are the "Where to send" and "What to light" settings, on the right are the lists of project devices and devices found on the network. At the bottom are the universe preview, the "Start sending" / "Stop" button and the status line: to which address, which universes, how many packets per second and through which adapter the sending goes.

📷 Здесь будет скриншот: The whole "Converter Test" window during sending: on the left "Addressing", "Universe", "Fixture type", "Color", "Area" are filled in; on the right the "Project devices" list; at the bottom the universe preview strip and the status line "Sending to …"

Where to send: address, adapter and universe

Addressing

Mode When to use
Single address The converter's IP is known. The main mode.
IP range It is unknown which converter has which address: the test goes to all addresses of the range at once, for example .200–.255. The preset buttons fill in typical ranges in the subnet of the selected adapter. No more than 256 addresses are sent to at a time.
Broadcast All devices in the adapter's subnet will see the packets. Suitable for a small isolated network and for converters that accept a broadcast stream.

In range mode, next to it is shown how many addresses there will be and the approximate load in packets per second. If addresses together with universes add up to too many, the utility sends only the first universes — this is stated next to the field.

Adapter

The network adapter is selected automatically by the subnet of the entered address. If the address does not fall into any subnet of the computer, select the adapter in the list manually. The message "Adapter not found — packets are not being sent" means there is no suitable network connection.

Universe

  • Universe — the Art-Net universe number, in the same numbering as in the port properties of LS4 converters.
  • Consecutive universes — how many universes to light starting from the specified one: this is how you check a whole port or a whole converter in one go.
  • PageUp / PageDown — the neighboring universe, with Ctrl — ten at a time. Works while the window is in focus, including during sending.

The universe you move away from is turned off: otherwise the converter would keep holding the last value, and it would be impossible to tell which of the two universes is lit now.

Project devices and network discovery

On the right are two lists — a hint, not a mandatory condition:

  • Project devices — converters of the open project (standalone and inside Player) with their addresses and universes. The search line above the list searches by name, IP and universe number.
  • Found on the network — devices that responded after pressing "Find on network", with the universes of their ports. The poll takes a couple of seconds and does not interrupt the project output.

Clicking a row of either list fills its address and first universe into the fields on the left. If nobody responded on the network, specify the converter by address manually: many third-party nodes do not respond to the poll but accept test packets.

📷 Здесь будет скриншот: The right part of the "Converter Test" window: the "Project devices" list with the search line and the "Found on the network" list after pressing "Find on network"

What to light

Setting What it sets
Fixture type RGB, RGBW or single-channel — how many channels one pixel occupies. This determines how many pixels fit into a universe (shown under the preview strip).
Color White, red, green, blue, off, or cycling R → G → B → W. For RGBW, "white" means precisely the W channel: this shows whether white is connected. A single-channel fixture lights to the set level with any color except "Off".
Level, % The brightness of the test.
Blink and Period, ms Blinking helps tell the fixtures under test from ones that are lit for another reason. Enabled by default, the period is 1 second.
Area Whole universe, Pixel range or Running pixel (with its own Step, ms).

Settings can be changed on the fly — sending picks them up immediately.

Universe preview

The strip at the bottom of the window shows exactly what is going to the network right now: the color of each pixel of the universe, blinking and the running pixel. It is also the most convenient way to set the range:

  • drag the edges of the selection to move the start or the end, and the middle to move the whole range;
  • dragging over an empty area sets a new range;
  • the mouse wheel changes the nearest boundary by 1, with Shift — by 10;
  • the left and right arrows move the end of the range, with Ctrl — the whole range.

Under the cursor the pixel number is shown; the last pixel of the universe is always labeled on the scale.

📷 Здесь будет скриншот: The "Universe preview" strip with a selected pixel range, the cursor over an edge handle and the pixel number label

Project sending during the test

The checkbox "Pause project sending during the test" is enabled by default: the converter accepts both streams from one computer, and the same universe would blink from two sources. Project output resumes automatically after "Stop" or closing the window.

If the checkbox is cleared, the window shows a warning: the test and the project will compete for the same universes.

When the window is closed, all universes lit by the test are turned off.

A port with several universes

Some converters turn on a port's output only after receiving all universes assigned to it. If you send one universe out of three or four to such a port, the strip will not light at all, even though the packets arrive. This is how, for example, LightStream SPI converters with firmware up to and including 1.2.62 behave.

If the strip stays silent with the correct IP and universe, set in "Consecutive universes" as many universes as the output has, starting from the first universe of the port. The hint under the universe fields reminds of the same.

Typical installation checks

Find which universe a strip has

  1. Enter the converter's IP or select it in the list.
  2. Set Color → White, Area → Whole universe, leave blinking enabled.
  3. Press "Start sending".
  4. Page through the universes with the PageUp / PageDown keys until the needed strip blinks. The number in the "Universe" field is the one you are looking for.

The converter's IP is unknown

  1. Choose "IP range" and a preset of the adapter's subnet (or "Broadcast").
  2. Specify the likely universe (usually the first) and start sending.
  3. When something lights up, narrow the range by half until one address remains.

Check channel connection

  1. Select the correct fixture type (RGB or RGBW).
  2. Enable "Cycle R → G → B → W" or switch the colors one by one.
  3. If "red" lights green or blue, the fixture has a different channel order; if white does not light on an RGBW, the problem is in the W channel.

Count the pixels in a strip

  • Running pixel: watch at which number the pixel reaches the end of the strip.
  • Pixel range: move the end of the range on the preview strip until the last pixel of the strip goes out.

The strip does not light

  • Check the status line: the packets are really going out and through the right adapter.
  • Try broadcast sending — maybe the converter has a different IP.
  • For a port with several universes, set all the port's universes, see above.
  • Check whether another Art-Net source on the network interferes — see "Art-Net not sending".

Related materials