Skip to content
Light StreamWiki
← Knowledge base
Page tools

Converter 6 rev.1 and rev.2 - User guide


Light Stream Converter 6


A converter with a built-in Ethernet switch and 6 configurable ports.

It converts an Art-Net signal to DMX or SPI to control lighting fixtures.

  • Quick setup over the network
  • 8V-48V DC or PoE power
  • "Standby scene" when there is no Art-Net stream
  • Full support of the Art-Net v4 protocol
  • Up to 2 Art-Net Universes per port (up to 3 for SPI fixtures)
  • Individual ports can work in DMX IN mode, full RDM compatibility
  • Galvanic isolation of the power and DMX ports



Specifications


Light Stream Converter 6 case size


Ergonomics

Case Metal, with additional mounting for DIN rail installation
Weight 420 g
Dimensions 148 mm • 108 mm • 34 mm

Interfaces

Ethernet ports 2 x 100 Mbit/s Ethernet ports (built-in switch)
Output ports 6 DMX out-in / RDM / SPI ports
Supported protocols Art-Net v4 (compatible with v1, v2, v3), DMX512 (classic and extended)
Channels per port 512 or 2048 (optional for SPI and high-speed DMX)
Supported SPI chips Any ICs with single-wire control, such as: UCS8903, GS8206, GS8208, WS2811, WS2812, WS2814, WS2818, SK6812, UCS1903, TM1804 and others
Galvanic isolation on ports Signal: optical

Power: up to 1000 V DC

Voltage and consumption 8-48V DC, PoE (type B) 24-48V DC up to 5 W
Power consumption 5 W (480mA@8V, 300mA@12V, 150mA@24V, 75mA@48V)
Power and output port connectors Pluggable screw terminal connectors for cables up to 1.5 mm²

Operating conditions

Operating temperature -40°C to +50°C
Storage temperature -50°C to +70°C
Humidity 5% to 85%, non-condensing
Electrostatic discharge immunity Air discharge ± 15 kV DC
IP rating IP20
Warranty 3 years limited manufacturer's warranty



Indication


Port connector and indicator labels of Light Stream Converter 6


Each indicator on the Converter can light in several colors:

  • green
  • red
  • orange (the red and green LEDs are on at the same time)


"Mode" indicator

The "Mode" indicator shows the state of the Art-Net stream:

  • lit red - no Art-Net data is arriving for the Universes assigned to the converter ports
  • blinks yellow - the Art-Net stream contains data for the Universes assigned to the converter ports


"Data" indicator

The "Data" indicator shows the state of the Ethernet ports:

  • lit or blinking green - data is arriving over the Ethernet network
  • off - no data is arriving


Output port indicators

Next to each port there is an indicator that shows its current state.

The indication types differ for each port operating mode:

In DMX-OUT mode

  • lit green - a DMX signal is being transmitted
  • lit green, occasionally goes off for 0.1 s - a DMX signal with ArtSync synchronization is being transmitted
  • off - no DMX signal is being transmitted

In DMX-OUT with RDM mode

  • blinks green - no DMX signal is being transmitted, searching for RDM fixtures
  • orange briefly - an RDM device has been found
  • lit green, occasionally turns on red for 0.05 s - a DMX signal is being transmitted, RDM data exchange is in progress in parallel
  • lit green, occasionally turns on red for 0.05 s, occasionally goes off for 0.1 s - a DMX signal with ArtSync synchronization is being transmitted, RDM data exchange is in progress in parallel

In DMX-IN mode

  • lit red - an incoming DMX signal is being received
  • blinks red - no incoming DMX signal

In SPI mode

  • lit orange - an SPI signal is being transmitted
  • lit orange, occasionally goes off for 0.1 s - an SPI signal with ArtSync synchronization is being transmitted
  • off - no SPI signal is being transmitted



Quick start

Step 1. Connecting power

Power can be supplied in two ways:

Option 1 Option 2*
From a 12V, 24V or 48V DC power supply


Powered by a 12V, 24V or 48V DC power supply

Over the Ethernet cable using PoE


Powered over the Ethernet cable using PoE

* - on the Light Stream Converter, only Ethernet port No. 2 supports PoE power.

For connection diagrams, see the section: "Connection diagrams".

Step 2. Connecting to the Ethernet network

Connect the Light Stream Converter to the same Ethernet network as Light Stream Player or the Light Stream software installed on a PC:

Option 1 Option 2 Option 3*
Connect Light Stream Player and all Converters to an Ethernet switch


Connecting Converter 6 to Ethernet - Connect Light Stream Player and all Converters to an Ethernet switch

Connect the first Converter to an Ethernet switch, the rest in a daisy chain to it


Connecting Converter 6 to Ethernet - Connect the first Converter to an Ethernet switch, the rest in a daisy chain to it

Connect the first Converter to the second port of Light Stream Player V2, the rest in a daisy chain to it

Connect the first Converter to the second port of Light Stream Player V2, the rest in a daisy chain to it

* - if you need to control the converters with the Light Stream software, a PC with suitable network settings must be connected to the second port of the last Converter in the chain.

For examples of connection diagrams, see the section: "Connection diagrams".

Step 3. Configuring Ethernet network parameters

The network settings of the Light Stream Converter must allow it to exchange data with Light Stream Player or the Light Stream software.

Option 1 Option 2
Use static IP addresses of the subnet 2 . * . * . * or 192 . 168 . * . * . Obtain network settings via DHCP
If there is no DHCP server in the Ethernet network, then with the default settings the Converter will stay on the static IP address in the subnet 2 . * . * . * (it is printed on the sticker on the back of the Converter case).

Or you can set another static IP address (then the automatic DHCP server search on connecting to the Ethernet network is disabled).

After connecting to Ethernet, a Converter with the default settings tries to obtain network settings via DHCP.

For correct operation, configure the DHCP server to issue IP addresses in the subnet 2 . * . * . * or 192 . 168 . * . * .

If the Art-Net stream will be sent via unicast (to a specific IP), you must also fix the IP addresses issued to the converters in the DHCP server settings so that they do not change in the future.

Examples of suitable settings

  • Option 1. Subnet 2 . * . * . *
    • 2 . 37 . 192 . 37 / 255 . 0 . 0 . 0 - Converter IP address / mask
    • 2 . 0 . 0 . 2 / 255 . 0 . 0 . 0 - Light Stream Player IP address / mask
  • Option 2. Subnet 192 . 168 . 0 . *
    • 192 . 168 . 0 . 180 / 255 . 255 . 255 . 0 - Converter IP address / mask
    • 192 . 168 . 0 . 2 / 255 . 255 . 255 . 0 - Light Stream Player IP address / mask


Important: Make sure that the IP addresses you choose are not used by other devices on your network. An IP address conflict can cause connection problems.

If you obtain settings via DHCP and need to send the Art-Net stream to the Converter via unicast, configure the DHCP server so that it always issues the same IP address to each particular Converter.


For more details on configuring network parameters other than the defaults, see the section: "Setup with Light Stream Player".

Step 4. Configuring the converter operating mode

The remaining settings must be made over the network using either the Light Stream Player web interface or the Light Stream software on a computer.

For more details on setup, see the section: "Setup with Light Stream Player".

Step 5. Configuring the "Standby scene" mode

After power-on and until an Art-Net signal arrives, the Converter sends the "Standby scene" (by default it is "blackout" - the value of all channels is 0) to all DMX / SPI ports.

If an Art-Net stream was being received but was interrupted, the last frame received by the Converter is sent statically to the ports. You can switch the Converter to the "Standby scene" by pressing a button on the case or by rebooting.

If you set up your own "Standby scene", the Converter will broadcast a preconfigured static scene rather than just "darkness". This is useful if, for example, some lighting is needed during the day or at night while the Ethernet network is unavailable or the Art-Net stream is not arriving for some reason.


For more details on setup, see the section: "Standby scene".



Connection diagrams

Power from a PSU via a bus, Ethernet from a switch in a star

A common connection diagram.


Light Stream Converter 6 connection diagram: power from a PSU via a bus, Ethernet from a switch in a star


Power from a PSU via a bus, Ethernet from a switch in a daisy chain

This connection diagram uses fewer switch ports. Short patch cords are convenient for connecting the converters to each other in an Ethernet daisy chain.


Light Stream Converter 6 connection diagram: power from a PSU via a bus, Ethernet from a switch in a daisy chain


Power from a PSU via a bus, Ethernet from LS Player V2 in a daisy chain

The second Ethernet port of Light Stream Player V2 is configured by default for the subnet 2 . * . * . * . Converters connected to it do not find a DHCP server and are then available at the default IP address in the subnet 2 . * . * . * . (it is printed on the sticker on the back of the Converter case).

This results in an isolated network for Art-Net converters with static IP addresses. Light Stream Player V2 interacts with them; you can both configure them and send the Art-Net stream via unicast.


Light Stream Converter 6 connection diagram: power from a PSU via a bus, Ethernet from LS Player V2 in a daisy chain


Power and Ethernet from a PoE switch in a star

Fast and easy connection thanks to a minimum of wires. The Light Stream Converter does not need a separate power supply. Only Ethernet port No. 2 supports PoE power.


Power and Ethernet from a PoE switch in a star



Default settings

Network settings

On power-up the device tries to obtain settings via DHCP.

If a DHCP server is not available, the device continues to work with the default static IP address and mask:

  • IP address - 2 . * . * . * (printed on the sticker on the back of the Converter case)
  • Mask - 255 . 0 . 0 . 0

Merge type

If several Art-Net streams arrive at the Converter simultaneously, the SINGLE merge type is used by default to process them.

Output port settings

  • Port 1 - DMX512 mode, U1
  • Port 2 - DMX512 mode, U2
  • Port 3 - DMX512 mode, U3
  • Port 4 - DMX512 mode, U4
  • Port 5 - DMX512 mode, U5
  • Port 6 - DMX512 mode, U6

Resetting settings

If "something went wrong" during setup, you can return the Converter settings to the default values at any time. For more details, see the section: "Service menu".


To configure Converter 6 you can use:

Option 1 Option 2
Light Stream Player


File:LS-Converter-6-v2-ru-Light-Stream-Player-V2.png

Light Stream software
on a computer

File:LS-Converter-6-v2-ru-PC-with-Light-Stream-software.png



Setup with Light Stream Player

To be able to configure the Light Stream Converter, it and Light Stream Player must be in the same Ethernet subnet (the IP addresses and masks allow them to exchange data).

In a browser on the PC, open the Light Stream Player web interface at its IP address on the local network (by default http://192.168.0.205 ).


"Art-Net devices" page

In the left side menu, in the "Devices" section, open the "Art-Net" item. The "Art-Net devices" table shows all devices that LS Player has seen on the network before or sees right now.

We are interested in devices with the type "Dmx converter" and a name like "LS Converter 6-767B0A", where "Converter 6" is the device model and "767B0A" is the last characters of the MAC address of the particular device.


File:LS-Converter-6-v2-ru-Setting-up-with-LS-Player--Artnet-device-page.png

  • Name - the device name
  • IP - the device address in the Ethernet network.
  • Software - the converter software version.
  • Status - the current state of the connection with the converter:
    • "Power On Tests successful" - the converter is on the network.
    • "Connection lost" - the connection with the converter is lost.
  • Ports - the number of converter ports for connecting DMX or SPI equipment.
  • RDM devices - the number of RDM DMX devices connected to the converter ports.
  • Actions - quick commands without opening the device card:
    • "Identify" - when this command is sent, all indicators on the Converter blink several times to quickly identify the converter visually.
    • "RDM devices" - quick jump to searching for RDM devices connected to the converter ports. Do not forget to first enable RDM on the ports you need.


Converter 6 settings pop-up window

To configure a converter, click anywhere on the row of the required converter on the "Art-Net devices" tab.

In the window that opens you see all available settings:


File:LS-Converter-6-v2-ru-Setting-up-with-LS-Player--Converter-settings-pop-up-window.png

  • Name - the displayed name of the converter.
  • Type - for Light Stream Converter devices the type is "DMX Converter".
  • Status - the current state of the connection with the converter:
    • "Power On Tests successful" - the converter is on the network.
    • "Connection lost" - the connection with the converter is lost.
  • IP - the device address in the Ethernet network.
    • Type
      • Static - set static network settings.
      • DHCP - obtain network settings automatically
    • IP address - the device address
    • Netmask - the device network mask
    • Gateway - the device gateway
  • Software - the Converter software version.
  • Merge type If the Art-Net Universes assigned to a Light Stream Converter port are present in several Art-Net streams arriving simultaneously from different IP addresses, a conflict occurs. You need to choose what will be played:
    • SINGLE (default)
    • MERGEHTP
    • DUALHTP
  • Ports - individual settings for each converter port:
    • # - the port sequence number.
    • Name - the system name of the port.
    • Out signal - selecting the type of output signal:
      • DMX - when devices controlled via the DMX protocol are connected to the port.
      • SPI - when an SPI-Extender and SPI light sources are connected to the port.
    • Universe - the number of the Art-Net Universe from the incoming Art-Net stream that will be broadcast to the devices connected to this converter port
  • RDM
    • "on" - enable the RDM protocol to find and control compatible devices on this port.
    • "off" - disable if no such devices are planned to be connected.
  • Tx - indication of signal playback on the port
  • DMX settings Editing the DMX signal settings. Do not change them if you do not understand why you would do so and what it will affect.
    • Available settings: Break time, Mab time, Chan time, Pause time, Channel count.
    • To send 2 Art-Net Universes to each port, change the "Channel count" value from 512 to 1024



Setup with Light Stream software

Check that the computer and the converters are in the same Ethernet subnet (the IP addresses and masks allow them to exchange data).

Open the Light Stream program on your computer. Create a new project. Go to the "Fixtures" tab.


File:LS-Converter-6-v2-ru-Fixtures.png


At the bottom, click the "Magnifier" icon to search for devices on the local network. The "Search Art-Net nodes" window will open.


File:LS-Converter-6-v2-ru-Search-Art-Net-nodes.png


In the "Network device" drop-down list, select the network card the converter is connected to.

Click the "Search" button to start searching for devices. The found devices will appear on the left side of the window.


File:LS-Converter-6-v2-ru-Search-Art-Net-nodes--Found.png


Select the required converter in the list. Brief information about it will appear on the right.

When you click the "Ping" button, all indicators on the selected converter blink several times. This way you can quickly identify all found Light Stream Converters.


Parameters available for configuration

To open the Light Stream Converter settings window, click the "Settings" button.


File:LS-Converter-6-v2-ru-Search-Art-Net-nodes--Device-settings.png


Changing IP settings

  • IP address - the current IP address of the converter.
  • Mask - the suggested mask value (regardless of which mask is currently set)

To change the IP address and mask, enter the required values, then click the "Set IP" button.


Other settings

  • Ping - sends the Ping command to the Light Stream Converter. When it is received, all indicators on the converter blink several times.
  • Full name - the converter name. You can change it and click the "Set" button to save.
  • Port mode - selecting the operating mode of the converter ports
    • DMX modes
      • DMX512 - full compliance with the 1990 DMX standard. 512 channels per port
      • DMX1024HS - a modern modification of the DMX standard. Thanks to the increased signal frequency, the number of channels on the line is doubled. Compatible with many light sources of Chinese manufacture. 1024 channels per port
    • SPI modes
      • SPI 170 pix
      • SPI 340 pix
      • SPI 680 pix x1
    • SPI chips if you selected an SPI port mode, you will need to specify the SPI chip used
      • GS8206
      • WS2814
      • WS2811
      • WS2811L
      • WS2812
      • WS2818
      • UCS1903
      • UCS8903
      • TM1803
      • TM1914
  • Ports - the list of Light Stream Converter ports, the selected type and the Art-Net Universes assigned to them. For example:
    • Short name - a short port name generated automatically depending on the selected mode and the port number
    • Universe - the number of the Art-Net Universe sent to the port The Art-Net Universe number can also be set the classic way:
      • Net - the net number
      • Subnet - the subnet number
      • Univ. - the universe number



Standby scene

Recording the "Standby scene"

  1. Start sending an Art-Net stream to the Converter with the static scene that you want to record as the "Standby scene".
  2. Using the indication, make sure that the Art-Net signal is arriving at the Converter and a DMX or SPI signal is being transmitted to the required ports.
  3. Hold the "Mode" button for 3 seconds until the "Mode" indicator starts blinking quickly
  4. The "Standby scene" is recorded.

Forced start of the "Standby scene"

  1. Using the indication, make sure that no Art-Net signal is arriving at the Converter.
  2. Press and hold the "Set" button for 1 second.
  3. The "Standby scene" is running.



Test animations

The converter revision number is printed on the sticker on the bottom of the case.

  • rev.1 — there are no test animations, and the firmware for this revision is not updated. You can check the fixtures only by sending an Art-Net stream: from a computer or Light Stream Player.
  • rev.2 — the firmware described in this article has no test animations. After updating to the new firmware (Converter 6 firmware on the website), one of the buttons becomes a test button — its operation is described in the section "Test animations mode" of the article Converter 6 - User guide.



Service menu

For quick settings you can use the service menu. It can be used even without connecting the Converter to the Ethernet network. All control is done with the "Mode" and "Set" buttons.

Available commands

Each command has its own blinking pattern of the "Data" indicator:

  • 1 time red, pause - reset the network settings to the default values
  • 2 times red, pause - reset the Converter port settings to the default settings
  • 1 time green, pause - switch to the "Static IP" mode
  • 2 times green, pause - switch to the "DHCP" mode
  • 3 times green, pause - save the IP address obtained via DHCP and make it static

Setup via the service menu

Step 1. Enter the menu

  • Disconnect power from the Converter
  • Press and hold the "Mode" button
  • Apply power
  • The converter turns on in service menu mode.

The "Mode" indicator will be lit orange, and you can release the "Mode" button.

Step 2. Select the required command

Press the "Mode" button to cycle through the service menu commands "in a loop". You can tell which command is currently selected by the blinking of the "Data" LED (see "Available commands" above).

Step 3. Execute the selected command

The command is executed by pressing the "Set" button.

Step 4. Exit the service menu

To exit you can use either of two ways:

  • press "Set" on an empty list item (the "Data" indicator is not blinking).
  • wait 60 seconds, and the Converter will reboot into normal mode.


Working with RDM

The Converter fully supports the RDM protocol. It passes all received RDM data to Light Stream Player using the Art-RDM protocol.

RDM is off by default. It is enabled on each port separately. For more details, see the section: "Converter 6 settings pop-up window".


If there is no Art-Net stream

"Standby scene" until the Art-Net stream appears

If no Art-Net stream arrives at the Converter after it is powered on, the Converter broadcasts the "Standby scene" to all ports.

When power is applied to the Converter, the lights will not turn on by accident, but will stay "off" or in the "Standby scene" you configured until the Art-Net stream appears.

By default the "Standby scene" contains the "black" ("blackout") signal. You can overwrite it with a static lighting scene for your site.

You can test the fixtures even without an Art-Net stream source. Also, this preconfiguration will not leave the site without lighting even if the Art-Net stream source is unavailable after the Converter is powered on.

As soon as an Art-Net stream arrives at the Converter, the data from the stream is broadcast to the ports.


If the Art-Net stream is interrupted

If the Art-Net stream disappears, the Converter broadcasts the last available data for all DMX channels until the Art-Net stream resumes (or until the Converter is turned off).

If there are communication interruptions between the Converter and the Art-Net signal source, the lights will not turn off or glow "chaotically". The animation will simply stop in a static position until the connection is restored.

If the Art-Net stream disappears, the "Standby scene" can be enabled in two ways:

  1. Disconnect the Converter from power and turn it on again
  2. Press the "Set" key on the Converter case once


Attention

Some DMX light fixtures can remember on their own the last DMX signal they received. Even after the Converter is turned off, they will keep playing it. For a complete reset, power must also be disconnected from the DMX fixtures.



Working with multiple Art-Net streams

The Converter can work not only with a single Art-Net stream but with several. This is useful both for redundancy and for merging two streams.

The Art-Net stream merge type on the Converter is selected for the whole device and applies to all its ports. How to set the required mode is described in the section: "Converter 6 settings pop-up window".


Single

In the Single merge type the converter uses only one Art-Net stream.

  • The converter remembers the IP address of the first Art-Net stream received and uses only its data. Streams from other IPs are ignored.
  • If the main stream is interrupted for more than 5 seconds, the converter automatically switches to the next available Art-Net stream, remembering its IP address.

Art-Net stream redundancy.

To increase reliability you can send the same Art-Net stream from two different IP addresses.

If the main stream is interrupted, after 5 seconds the converter automatically switches to the backup.


MergeHTP

In the MergeHTP merge type the converter combines two Art-Net streams from different IP addresses, choosing the maximum value for each DMX address.

  • The Converter can process only two Art-Net streams from different IP addresses at the same time; additional streams are ignored.
  • If one of the two Art-Net streams is interrupted, after 5 seconds the Converter switches to the next available Art-Net stream.

Playing two Art-Net streams from different IP addresses.

This can be useful if you need to combine effects from two sources at different IP addresses.

For example, the source of the first Art-Net stream sends a calm animation, and the source of the second sends a "Fireworks" animation at the right moment.

The Converter combines these streams, and the "Fireworks" animation is played on top of the calm animation.


DualHTP

In the DualHTP merge type each converter port combines two independent Art-Net Universes, choosing the maximum value for each DMX channel.

  • The numbers of two Art-Net Universes are specified for each port.
  • The Art-Net stream sources can be at different IP addresses or at the same one.

Controlling one DMX port from two programs on one computer.

Imagine you need to connect DMX lighting fixtures and a DMX relay to one Converter port and control them simultaneously, using different software on one computer.

One program controls the lighting (U3, DMX channels 1-449), and the other controls the DMX relay (U120, DMX channels 450-512). In DualHTP mode, U3 and U120 are assigned to one port.

The Converter will receive data from U3 for channels 1-449 and from U120 for channels 450-512, sending the maximum values for each channel to the port.



Package contents

Light Stream Converter 6 - 1 pc.

Ethernet cable - 1 pc.

Connectors - 2 pin 1 pc., 3 pin 6 pcs.


Disposal

A device that has reached the end of its service life or has failed must be disposed of in accordance with the applicable legislation of the Russian Federation.

The packaging can be fully recycled.


Manufacturer's warranty

The warranty period is: 3 calendar years from the date of sale.

The warranty covers cases of device failure provided that the operating rules and climatic conditions are observed.

The warranty becomes void if the Buyer has made changes to the device's configuration, or if the device case or board shows mechanical damage, traces of liquids, burning, or opening.

Warranty replacement and repair are performed at the Seller's address.


Support


File:Telegram-icon--In-circle.png


If you have any questions, you can ask them in the technical support chat on Telegram:

https://t.me/lightstreamchat